An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters

2008

This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.

EngineeringTotal harmonic distortionbusiness.industryAcousticsAstrophysics::Instrumentation and Methods for AstrophysicsAC powerMetrologyElectric power systemHarmonicsHarmonicElectronic engineeringMetreenergy measurements harmonic distortion power quality power systemsbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage2008 IEEE Instrumentation and Measurement Technology Conference
researchProduct

Metrological characterization and operating principle identification of static meters for reactive energy: an experimental approach under nonsinusoid…

2009

In this paper, an experimental approach is proposed for the metrological characterization of the static meters for reactive energy and for the individuation of their operating principle in nonsinusoidal conditions. The proposed approach was developed by starting from the only available accuracy test condition in the presence of the harmonics introduced by the standards for active static meters. In this paper, the proposed approach is described, and some experimental tests are presented, which were performed on some meters of different accuracy classes and with both known and unknown operating principles.

Total harmonic distortionEngineeringbusiness.industryControl engineeringCharacterization (materials science)MetrologyIdentification (information)Electric power systemHarmonicsElectrical and Electronic EngineeringbusinessInstrumentationAccuracy classSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltageEnergy measurements harmonic distortion power quality power systems static meters
researchProduct

On the calibration of reactive energy meters under non sinusoidal conditions

2009

This paper is focused on the problems related to the calibration of the reactive energy meters on the place of installation of the electricity meter (on-site), using the load of the same electrical system. In the presence of harmonic distortion, the behaviour of the meters can go out of the limits imposed by the theoretical calibration curve depending on the metric used by both reference standard meters and meters under test.

energy measurements harmonic distortion reactive energy metersSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Energy measurements at Skarpnes zero energy homes in Southern Norway: Do the loads match up with the on-site energy production?

2017

Five houses are designed as zero-energy homes in Skarpnes, Norway. The energy goal is to achieve net zero-energy balance on an annual basis. The houses have heat pumps and solar cells (PV). Energy use and delivered energy have been monitored from June 2015. Variations between calculations and measurements are explained by technical and non-technical reasons. For the first year, higher than expected energy loads result in a solar energy cover factor of 65–87% of delivered electricity. The PV generation performs satisfactorily, hence, it may be possible to achieve energy goals during later years provided technical adjustments or behavioral changes. Acknowledgements. This report has been writt…

EngineeringArchitectural engineering020209 energyZero emission building; ZEB02 engineering and technologyZero energy buildings:Teknologi: 500 [VDP]Energimålinger0202 electrical engineering electronic engineering information engineeringProduction (economics)Energy measurementsZero emissionPhotovolatic systemZero-energy buildingNorwaybusiness.industry:Technology: 500 [VDP]VDP::Technology: 500Fotovoltaisk systemBuilding energy simulationsVDP::Teknologi: 500Null energibyggResearch centreResearch councilBygninger energisimuleringerElectricitybusinessZero energy homesEnergy Procedia
researchProduct

The Measurement of Reactive Energy in Polluted Distribution Power Systems: An Analysis of the Performance of Commercial Static Meters

2008

This paper presents a comparative analysis of the performances of both a traditional induction meter and various types of commercial static meters for reactive energy in the presence of harmonic distortion. This is a topical issue, since there are several types of static meters on the market, based on different principles of construction. In accordance with current standards, these meters are designed to operate in sinusoidal conditions and their performance is not tested in the presence of harmonic distortion. However, with the increase of pollution levels in power systems, the meters may be used even in the presence of distorted voltages and/or currents; in such cases, their accuracy may …

Total harmonic distortionEngineeringbusiness.industryElectrical engineeringEnergy Engineering and Power TechnologyAC powerAutomotive engineeringPower (physics)law.inventionElectric power systemlawElectrical networkEnergy measurements induction meters power systems harmonics reactive power static metersMetreElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheEnergy (signal processing)VoltageIEEE Transactions on Power Delivery
researchProduct

Static meters for the reactive energy in the presence of harmonics: an experimental metrological characterization

2009

Electricity metering plays a crucial role for all the commercial transactions on the energy market. Thus, an accurate evaluation of the performance of the electricity metering equipment is required not only in the reference operating conditions but also in the presence of disturbances affecting the power systems. As regards this matter, this paper analyzes the main aspects related to the metrological characterization of the static meters for the reactive energy in the presence of harmonic distortion. Attention is focused not only to the meters covered by the current standards but also to the meters of better accuracy and to the reference standard meters. The analysis is supported by several…

EngineeringTotal harmonic distortionbusiness.industryComputingMethodologies_MISCELLANEOUSElectrical engineeringenergy measurements reactive power static meters reference standard meters power systems harmonicsAC powerAutomotive engineeringElectric power systemHardware_GENERALHarmonicsEnergy marketMetering modeElectricityElectrical and Electronic EngineeringbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct