An harmonic test condition for the metrological characterization and the operating principle identification of reactive static meters
2008
This paper faces the problem of the metrological characterization of the static meters for reactive energy in the presence of harmonic distortion. Starting from the only available accuracy test condition in the presence of harmonics introduced in the Standards for active static meters, an experimental approach is proposed for the verification of such meters in the presence of harmonic distortion, as well as for the individuation of their operating principle. A theoretical validation of the obtained results is presented by means of a comparison with a standard and a commercial static meter with a known operating principle.
Metrological characterization and operating principle identification of static meters for reactive energy: an experimental approach under nonsinusoid…
2009
In this paper, an experimental approach is proposed for the metrological characterization of the static meters for reactive energy and for the individuation of their operating principle in nonsinusoidal conditions. The proposed approach was developed by starting from the only available accuracy test condition in the presence of the harmonics introduced by the standards for active static meters. In this paper, the proposed approach is described, and some experimental tests are presented, which were performed on some meters of different accuracy classes and with both known and unknown operating principles.
On the calibration of reactive energy meters under non sinusoidal conditions
2009
This paper is focused on the problems related to the calibration of the reactive energy meters on the place of installation of the electricity meter (on-site), using the load of the same electrical system. In the presence of harmonic distortion, the behaviour of the meters can go out of the limits imposed by the theoretical calibration curve depending on the metric used by both reference standard meters and meters under test.
Energy measurements at Skarpnes zero energy homes in Southern Norway: Do the loads match up with the on-site energy production?
2017
Five houses are designed as zero-energy homes in Skarpnes, Norway. The energy goal is to achieve net zero-energy balance on an annual basis. The houses have heat pumps and solar cells (PV). Energy use and delivered energy have been monitored from June 2015. Variations between calculations and measurements are explained by technical and non-technical reasons. For the first year, higher than expected energy loads result in a solar energy cover factor of 65–87% of delivered electricity. The PV generation performs satisfactorily, hence, it may be possible to achieve energy goals during later years provided technical adjustments or behavioral changes. Acknowledgements. This report has been writt…
The Measurement of Reactive Energy in Polluted Distribution Power Systems: An Analysis of the Performance of Commercial Static Meters
2008
This paper presents a comparative analysis of the performances of both a traditional induction meter and various types of commercial static meters for reactive energy in the presence of harmonic distortion. This is a topical issue, since there are several types of static meters on the market, based on different principles of construction. In accordance with current standards, these meters are designed to operate in sinusoidal conditions and their performance is not tested in the presence of harmonic distortion. However, with the increase of pollution levels in power systems, the meters may be used even in the presence of distorted voltages and/or currents; in such cases, their accuracy may …
Static meters for the reactive energy in the presence of harmonics: an experimental metrological characterization
2009
Electricity metering plays a crucial role for all the commercial transactions on the energy market. Thus, an accurate evaluation of the performance of the electricity metering equipment is required not only in the reference operating conditions but also in the presence of disturbances affecting the power systems. As regards this matter, this paper analyzes the main aspects related to the metrological characterization of the static meters for the reactive energy in the presence of harmonic distortion. Attention is focused not only to the meters covered by the current standards but also to the meters of better accuracy and to the reference standard meters. The analysis is supported by several…